Casing and Tubing Leak Sealant Services
In Algeria, a gas injector well had tubing leaks at depths above the safety valve. Injection pressure was 5050 psi. After bleeding off pressure from the P1 annulus, the pressure would increase at a rate of 150 to 200 psi per hour through the tubing leak. During the Seal-Tite operation, the leak path was established by injecting gas and venting the P1 annulus. While injecting gas, Seal-Tite sealant was atomized into the gas stream. A differential pressure was created from the tubing to the P1 annulus and the sealant was carried through the leak path with the injection gas. The sealant polymerized in the leak path and sealed the leak. At the conclusion of the sealant operation, the P1 annulus was shut-in. The shut-in P1 pressure stabilized to 35 psi.
Seal-Tite International, 1795 West Causeway Approach, Suite 201, Mandeville, LA 70471. Tel: 888-674-3385; Fax: 504-626-9416.